BURNER RIELLO GAS GAS 6/2 300/520 ÷ 1050 kW TWO STAGE
Technical Datasheet Type Gas 6/2
MODEL : GAS 6/2
Burner operation mode : Two stage
Modulation ratio at max. output : 2 ÷ 1
Servomotor : LKS210
Heat output : kW 300/520÷1050
Heat output : Mcal/h 258/447÷903
Working temperature °C : min./max. 0/40
Net calorific value LPG gas ... Read More
Category: Uncategorized
10
Jan2025
BURNER RIELLO GAS GAS 5/2 155/320 ÷ 660 kW TWO STAGE
Technical Datasheet Type Gas 5/2
MODEL : GAS 5/2
Burner operation mode : Two stage
Modulation ratio at max. output : 2 ÷ 1
Servomotor : LKS210
Heat output : kW 155/320÷660
Heat output : Mcal/h 133/275÷568
Working temperature °C : min./max. 0/40
Net calorific value LPG gas ... Read More
January 10, 2025boilersburner
10
Jan2025
BURNER RIELLO GAS GAS 4/2 120/180 ÷ 470 kW TWO STAGE
Technical Datasheet Type Gas 4/2
MODEL : GAS 4/2
Burner operation mode : Two stage
Modulation ratio at max. output : 2 ÷ 1
Servomotor : LKS210
Heat output : kW 120/180÷470
Heat output : Mcal/h 104/155÷404
Working temperature °C : min./max. 0/40
Net calorific value LPG gas ... Read More
January 10, 2025boilersburner
10
Jan2025
BURNER RIELLO GAS 3/2 80/130 ÷ 350 kW TWO STAGE
Technical Datasheet Type Gas 3/2
MODEL : GAS 3/2
Burner operation mode : Two stage
Modulation ratio at max. output : 2 ÷ 1
Servomotor : LKS210
Heat output : kW 80/130÷350
Heat output : Mcal/h 69/112÷301
Working temperature °C : min./max. 0/40
Net calorific value LPG gas kWh/Nm3 ... Read More
January 10, 2025boilersburner
10
Jan2025
RIELLO RL 250 MZ RL 250 MZ 600/1250 ÷ 2700 kW LIGHT OIL TWO STAGE
TECHNICAL DATA MODEL RL 250
Burner operation mode Two stage
Modulation ratio to max. output 2 ÷ 1
type Servomotor LKS 210 run times– 7
Heat output kW 1250 ÷ 2700
Mcal/h172/1050 – 2115
Working temperature °C min./max. 0/40
FUEL/AIR DATA
Net calorifi c ... Read More
January 10, 2025boilersburner
10
Jan2025
BURNER RIELLO RL 190 759/1423 ÷ 2443 kW LIGHT OIL TWO STAGE
TECHNICAL DATA MODEL RL 190
Burner operation mode Two stage
Modulation ratio to max. output 2 ÷ 1
type Servomotor LKS 210 run times– 7
Heat output kW 1250 ÷ 2700
Mcal/h172/1050 – 2115
Working temperature °C min./max. 0/40
FUEL/AIR DATA
Net calorifi c value kWh/kg 11,8
Kcal/kg 10.200
Viscosity ... Read More
January 10, 2025boilersburner
10
Jan2025
BURNER RIELLO RL 130 486/948 ÷ 1540 kW LIGHT OIL TWO STAGE
TECHNICAL DATA MODEL : RL 130 TYPE : 662 T1
OUTPUT DELIVERY (1) 2nd stage : 948 – 1540 kW , 816 – 1325 Mcal/h , 80 – 130 kg/h
OUTPUT DELIVERY (1) 1st stage : 486 – 948 kW , ... Read More
January 10, 2025boilersburner
09
Jan2025
BURNER RIELLO RL 100 356/711 ÷ 1186 kW LIGHT OIL TWO STAGE
DATA TEKCNICAL BURNER RIELLO RL 100
Burner operation : 2 Tahap (Two stage / Dua Nozzle)
Modulation ratio at max. output : 2 ÷ 1
Heat output : 356/711÷1186 kW
Heat output : 306/612÷1020 Mcal/h
Bahan Bakar : Solar 30-100 Liter/jam
Tipe Control box : ... Read More
January 9, 2025boilersburner
09
Jan2025
BURNER RIELLO RL 70 255/474 ÷ 830 kW LIGHT OIL TWO STAGE
TECHNICAL DATA MODEL : RL70 TYPE : 660 T1
OUTPUT DELIVERY (1) 2nd stage : 474 – 830 kW , 408 – 714 Mcal/h , 40 – 70 kg/h
OUTPUT DELIVERY (1) 1st stage : 255 – 474 kW , 219 ... Read More
January 9, 2025boilersburner
09
Jan2025
BURNER RIELLO RL 64 MZ 206/391 ÷ 830 kW LIGT OIL TWO STAGE
DATA TEKNIKAL BURNER RIELLO RL 64MZ
Electrical Power Consumption (W max)1800
Electrical Supply (V, Hz)230 - 400 VAC with neutal ± 10%, 50/60 - three phase
Fuel Light Oil
Operat Intermittent (min. 1 stop in 24 hours)
Two-stage (high and low flame) and ... Read More
January 9, 2025boilersburner